Guide
How radon mitigation actually works — the physics and the install
Plain-English explanation of radon mitigation systems — how sub-slab depressurization moves air, why the fan + vent stack matters, and what success looks like.
A radon mitigation system uses pressure differential to redirect radon-laden soil gas away from your home. The most common system — sub-slab depressurization (SSD) — installs a fan that draws air from under the basement slab and vents it above the roofline. Done correctly, it reduces indoor radon by 50-99%, typically dropping levels below the 4 pCi/L EPA action threshold within 24-72 hours of activation.
The physics in one paragraph
Radon is a heavy radioactive gas (specifically radon-222, the longest-lived radon isotope) that's continuously produced by uranium decay in soil and bedrock. It rises through soil pores under slight upward pressure. When a home's foundation is intact, much of that radon vents harmlessly to outdoor air. But homes create stack-effect (warm air rising) that creates negative pressure at the foundation level — pulling radon-laden soil gas IN through cracks, the slab-to-wall joint, sump pits, and openings around pipes. A mitigation system reverses that pressure differential under the slab, so soil gas vents up the system stack rather than into the home.
Sub-slab depressurization (SSD) — most common system
What gets installed
-
Suction point — a 4" plastic pipe inserted through the basement floor into the gravel layer beneath the slab. Sometimes two points if the slab is large or has separate gravel zones.
-
PVC pipe run — 3-4" diameter, runs vertically through the home (often inside an interior wall or chase, sometimes via a utility room) up to and through the attic, exiting above the roofline.
-
Mitigation fan — installed in the attic or on the exterior of the home. Specialized low-power fan (RadonAway RP145, RP265 are industry standards). Runs continuously, draws 60-110 watts.
-
U-tube manometer — small clear plastic tube mounted to the visible pipe, with fluid that shows the pressure differential between system stack and ambient. Lets you visually verify the fan is working.
-
Roof vent cap — exhaust point typically 10+ ft above grade, 10+ ft from any openable window.
Standard install timeline
- Day 1, hours 0-3: site survey + suction point installation (drill core through slab)
- Day 1, hours 3-6: PVC pipe run from suction point to attic
- Day 1, hours 6-8: fan installation + electrical wiring + roof vent
- Day 1, hours 8-9: commissioning + manometer mounting
A typical install completes in 4-6 hours for a standard basement home. Crawl-space-only homes (sub-membrane systems) take 6-8 hours. Multi-zone or block-wall systems can take 1-2 full days.
Visible result
The fan creates negative pressure under the slab — usually -50 to -150 Pascals — drawing soil gas continuously up the stack and out above the roofline. The manometer shows the pressure differential as a fluid-column reading.
Within 24-72 hours of activation, indoor radon levels typically drop:
- 90-99% reduction for properly-sealed homes
- 50-90% reduction for homes with significant air leakage
Other mitigation systems (less common)
Sub-membrane depressurization (SMD)
For crawl-space homes. Same physics as SSD, but the suction point pulls from beneath a sealed plastic membrane covering the dirt floor (rather than from under a concrete slab).
Install: $1,200-$3,500 typical (more variable than SSD because membrane install is part of scope).
Block-wall depressurization
For homes with hollow concrete block foundations where radon migrates through the block cores. The mitigation system draws air from inside the block walls themselves.
Install: $1,500-$4,500 typical. Specialty work — fewer contractors do this competently.
Heat recovery ventilator (HRV)
A different physics: instead of pressure differential, an HRV creates positive ventilation throughout the home. Pushes radon out via dilution rather than re-routing it.
Install: $2,500-$6,500. Reserved for homes where SSD/SMD isn't feasible (high radon levels combined with foundation conditions that prevent active depressurization).
Increasingly used in modern tight homes (post-2010 ENERGY STAR construction) where the home is sealed enough that SSD alone can pull dangerous quantities of conditioned air out the stack.
Sump-pump cover seal + active venting
When the home already has a sump basin and the radon entry path is primarily through that basin: seal the sump cover, run a vent pipe + fan from inside the sealed basin up through the roof.
Install: $600-$1,800. Smallest scope system.
What "success" looks like
Industry standard: indoor radon below 4 pCi/L confirmed by a long-term test (90+ days) AFTER mitigation is installed.
Reputable contractors guarantee this and include a post-mitigation re-test ($150-$300) in the quote.
Some scenarios:
- Initial reading 8 pCi/L → post-mitigation typical 0.8-1.5 pCi/L (80-90% reduction)
- Initial 15 pCi/L → post-mitigation typical 1.5-2.5 pCi/L
- Initial 40 pCi/L → post-mitigation typical 3-6 pCi/L (may need 2-pipe enhanced system)
- Initial 100+ pCi/L → may need multi-stage or HRV combined with SSD
When the system underperforms
The 5-10% of installs that don't reach below 4 pCi/L on first test typically have:
-
Air leakage in suction zone — slab has unsealed cracks or gaps that pull conditioned air from the basement instead of pulling soil gas. Fix: seal cracks + slab-to-wall joints ($200-$600 added).
-
Insufficient fan capacity — fan undersized for slab area or sub-slab gravel layer depth. Fix: upsize fan ($300-$500).
-
Block-wall pathway not captured — radon entering through hollow block walls that the SSD system doesn't reach. Fix: add a second suction point to the wall ($500-$1,200).
-
Sump pit not sealed — sump cover allowing soil gas to bypass the system. Fix: gasketed sealed sump cover ($150-$300).
All of these are addressable with $200-$1,200 in additional work. Reputable contractors include re-mitigation in their warranty if first test shows above 4 pCi/L.
Maintenance
Annual:
- Check manometer fluid level (top up with mineral oil if low)
- Verify fan is running (audible hum from attic or exterior)
- Test for radon every 1-2 years to confirm system performance
Every 5-15 years:
- Replace fan (60-110W fans typically last 5-15 years)
- Cost: $300-$500 including labor
Every 5-10 years:
- Re-seal suction points if cracks develop
Operating cost
The fan runs continuously, drawing 60-110 watts. Electricity cost:
- 80W average × 24h × 365 days = 700 kWh/year
- At $0.13/kWh national average: ~$91/year
- Range across electricity markets: $50-$160/year
Minor heating loss from drawing conditioned air through the slab:
- Estimated 200-400 cubic ft/min of conditioned air pulled into the system
- Annual cost: $40-$120/year in additional HVAC load
Total annual operating cost: ~$130-$280/year. Lower in mild climates, higher in cold climates with high heating costs.
What the system does NOT solve
- Existing radon decay products in indoor air — these decay quickly (half-life 30 minutes) and clear within hours of mitigation activation. Not a long-term concern but explains why you should re-test 30-90 days post-install, not 1-2 days.
- Bath water or well water radon — separate issue. Some private wells in granite-bedrock regions deliver radon-laden water. Requires aeration tank or granular activated carbon (GAC) filter at point-of-entry. Different remediation system.
A properly-designed SSD system is the single most cost-effective health remediation in residential construction. $1,500-$2,500 reduces lung-cancer risk dramatically and operates for 15+ years with minimal maintenance.